⌂ Home

Transmission Line Standing Waves

v1.01
Drag probe · adjust sliders · change termination

Standing Waves

v1.01  ·  2026

What this shows

A standing wave forms on a transmission line whenever a signal reflects at the termination. Three lanes show the forward wave, reflected wave, and their superposition. The gold probe reads voltage and current at any point along the line.

Controls

Preset buttonsShort / Open / Matched — snap to standard terminations |Γ| sliderReflection magnitude: 0 = matched, 1 = full reflection φ sliderPhase of Γ: 0° = open, ±180° = short, ±90° = reactive Z toggleSwitch to impedance entry (R + jX, Z₀ = 50 Ω) Probe sliderMove the gold probe; readout shows V and I at that position ☾ / ☀Toggle light / dark mode

Readout panel

Probe positionDistance from load in wavelengths Voltage / CurrentNormalised V/V&sup+; and I·Z₀/V&sup+; at probe Reflected power|Γ|² × 100 % ZˆL, SWR, ΓLoad impedance, voltage standing wave ratio, reflection coefficient Return loss−20 log₁₀|Γ| in dB

About

Part of the free RF & microwave toolkit at clivepoole.com — Dr Clive Poole, Expert Solutions Limited.

A standing wave forms on a transmission line whenever a signal is reflected at the termination. This animation shows the forward-travelling wave, the reflected wave, and their superposition — the standing wave. Change the termination to see how the node and antinode pattern responds.

Probe position (from load)— Voltage (norm.)— Current (norm.)— Reflected power— ZˆL (Ω)— SWR— Γ— Return loss (dB)—
1.0×
¼λ
Γ (magnitude + phase)
Z (resistance + reactance)
|Γ| — magnitude  (0 = matched, 1 = full reflection)
1.00
φ — phase of Γ  (0° = open, ±180° = short, ±90° = reactive)
0°
Move sliders to set a custom load — preset buttons still work.

Current mode

Open circuit — full reflection, Γ = +1. Voltage maximum at the open end.

How to read this diagram

The cyan wave travels right (toward the load). The orange wave travels left (the reflection). Their sum — the white trace — is what you would measure at any fixed point on the line. The green markers show voltage nodes (V = 0). The shaded envelope shows the standing wave pattern amplitude.

Boundary conditions

Short circuit: voltage must be zero at the termination → voltage node at the end, current antinode. Γ = −1, SWR = ∞.

Open circuit: current must be zero → voltage antinode at the end, current node. Γ = +1, SWR = ∞.

Matched load: no reflection. Γ = 0, SWR = 1.

Measuring with the probe

Drag the probe slider to move the detector along the line. The readout above shows the instantaneous voltage — just as the Schottky-diode probe on the Lecher line would deflect. Both the normalised voltage (V/V⁺) and normalised current (I·Z₀/V⁺) are shown in the readout. Node positions (V = 0) are spaced exactly λ/2 apart regardless of termination type.